- search hit 1 of 1
Measuring altered movement patterns of musicians - Accuracy of a Motion Capturing System outside laboratory conditions
- No loss of accuracy out of lab. Large volume (long distance of cameras) leads to merging of close markers. No conclusion about accuracy when markers are changing positions. However: no assessment of accuracy possible due to missing gold Standard. No guarantee of accuracy with calibration by wand.
Author: | Christoff ZalpourORCiD, Dirk Möller, Nikolaus Ballenberger, Eduard WolfORCiD |
---|---|
Title (English): | Measuring altered movement patterns of musicians - Accuracy of a Motion Capturing System outside laboratory conditions |
URN: | urn:nbn:de:bsz:959-opus-10435 |
Document Type: | Conference Proceeding |
Language: | English |
Year of Completion: | 2018 |
Release Date: | 2018/09/07 |
Note: | MusicPhysio 2018 – 2. Internationaler Kongress zu Musikergesundheit in Osnabrück |
Faculties: | Fakultät WiSo |
DDC classes: | 600 Technik, Medizin, angewandte Wissenschaften / 610 Medizin, Gesundheit |
Review Status: | Unveröffentlichte Fassung |